| ITEM NAME | PROBLEM | PROBLEM REASON | CORRECTIVE ACTION |
| ONE PIECE CLOSET | Water not coming in bowl area while flushing | Water line not cleaned properly | before installation clean the imcoming as well as out going line |
| malfunctioning of mechanism of inside tank | change the mechanism | ||
| no water in the flush | raise the height change slot to the max level | ||
| 2. Leaking of water in bowl area | Push button is locked | Release the push button | |
| Fitment of mechanism end part and outlet of tank not fitted properly | After opening the mechanism check the fittment | ||
| Malfunctioning of mechanism inside tank | Change the mechanism | ||
| 3. Insufficient water quantity for effective flushing | Height change slot adjusted at lower level | Closet is not levelled properly | |
| 4. Uneven flow of water from both side of closet | Raise the height change slot to the max level | Level the closet properly | |
| Wall Hung Closet | 1. Water not coming in bowl area while flushing | Flush valve/concealed cistern is not working | Change the flush valve / concealed cistern |
| Flush pipe is not inserted up the end of inlet hole | Insert the flush pipe upto the end of inlet | ||
| 2. Leaking of water in bowl area | Closet is not levelled | Level the closet properly | |
| 3. Insufficient water quantity for effective flushing | Connection between closet outlet and drainage pipe is improper | Engage experienced plumber for proper connection | |
| Wash Basins / Table Top | 1. Overflow chocked and foul smell | Full threaded waste coupling might be in use | Replace it by slot cut coupling |
| 2. Water logging in platfrom and bowl area | Bracket and basin fixing may be the reason | Levelling to be checked and rectified | |
| 3. No tap hole in the basin | Tap hole is semi punched from back side | Call plumber and open up the semi punched hole | |
| EWC/Pan/Anglo Indian | 1. Water not coming in bowl area while flushing | Flush bend is not inserted up to the end of inlet hole | Insert the flush pipe upto the end of inlet |
| Levelling issue | To be levelled properly | ||
| Couple Closet (2 Pcs Closet) |
1. Uneven Flow Of Water From Both Side Of Closet Bowl | Both Arm Of Diverter Pipe Not Inserted Equally In Both Side Of The Closet | Both Arm Of Diverter Pipe Should Be Inserted Equally In Both Side Of The Closet |
| 2. Water Is Leaking Between The Cistern And Closet | Diverter Pipe Not Fixed Properly in The Outlet Of Cistern | Diverter Pipe Should Be Fixed Properly In The Outlet Of Cistern | |
| Rubber Ring Containing Bolt Is Not Tightened Properly | Rubber Ring Containing Bolt Should Be Tightened Properly |